Know More
Performance (at 25℃ ambient temperature and 45℃ equipment operating condition) | |
| Inner box dimension | Single box: 155188110 (WHD cm), total 5 boxes |
| Outer box dimension | 1. 11002560160 (WHD cm); 2. Total height after removing the motor: 223 cm; 3. Dimension for single - unit transportation: 2002230160 (WHD cm) |
| Temperature range | 25℃ ~ 60℃ |
| Temperature stability | No - load: ±0.3℃; Full - load: ±0.5℃ |
| Temperature deviation | No - load: ±1℃; Full - load: ±2℃ (measured at the inlet side of the trolley) |
| Temperature uniformity | No - load: 2℃; Full - load: 3℃ (measured 10 cm from the inlet of the trolley); Note: The temperature difference between the inlet and outlet of the trolley at full - load is about 10 - 12℃ |
| Temperature overshoot | No - load for single box: ≤2℃; Full - load for single box: ≤6℃ (under the condition of 32KW pure heat generation, increasing by 3.2KW in sequence, total time 30s); ≤3℃ (under the condition of 32KW pure heat generation, increasing by 3.2KW in sequence, total time 60s) |
| Heating - up time | No - load: RT to 45℃ takes about 5 minutes |
| Cooling - down time | 45℃ to 25℃ takes about 5 minutes (ice water temperature is 15℃) |
| Circulating air volume | Maximum about 6000cfm for single box |
| Maximum load capacity | Maximum heat generation load at 45℃ is 32KW pure heat generation (single box) |